Anesthetic flowmeter
Current position:Home > Anesthetic flowmeter

Type of production:Anesthetic flowmeter
Productname:Five-Tube Flowmeter O2-N2O-AIR
Model:WME FA-001/WME FA-101
Application:Used for anesthesia machine
Inquiry:

Wondcon WME FA-001/WME FA-101

N2O and O2 both have two tubes

When flow < 1 L/min use Low flow tube

When flow > 1 L/min use High flow tube

Gear/ORC Shape

Standard of Label:CE,CFDA,FDA

Shape of Knob:optional

Height of Knob:optional

Inlet:

O2:Φ6mm/Φ8mm straight/ “L” type

N2O:Φ6mm/Φ8mm straight/“L”type

Alr:Φ6mm/Φ8mm straight/ “L” type

Outlet:Φ6mm/Φ8mm straight/ “L” type

Sequence ofO2N2O and AIR:optional

Size of OEM:optional

Customization FA-001

IP{lnlet pressure}:

IP1: with reducer arbitrary from 0.2 to 1 MPa

IPO: without reducer

RN(FIow range of N2O):

RNX/y/z

x: from 0.1-15 L/min means the max scale of the N2O tube.

y: from15-22L/minmeans max safety flowof N2O over the axscale.

z: from 0-1 mL/min means the N2O leakage

with flow valve fully closed at 0.2 MPa.

L(Total Leakage):

Lx: x from 0-10 L/min means total

leakage at 0.2 MPa.

A(Flow Accuracy):Ax: x% is 10% of reading or better.

RA(Flow range of Air):

RAX/y/z

x: from 0.1-15 L/min means the max scale of the Air tube.

y: from 15-22 L/min means max safety flow of Air over the max scale.

z: from 0-5 mL/min means the leakage

with flow valve fully closed at 0.2 MPa.

CO(O2 Concentration): COx: x% is more than 25%

Optional function

1: N2O pressure cut off valve

2: Back light

3: The switch between N2O and air

4: When there is no O2 the Air gas turns on automatically

5: O2 flush device

0: No optional function

Customization FA-101

IP{lnlet pressure}:

IP1: with reducer arbitrary from 0.2 to 1 MPa

IPO: without reducer

RN(FIow range of N2O):

RNX/y/z

x: from 0.1-15 L/min means the max scale

of the N2O tube.

y: from15-22L/minmeans max safety flow of N2O over the maxscale.

z: from 0-1 mL/min means the N2O leakage

with flow valve fully closed at 0.2 MPa.

L(Total Leakage):

Lx: x from 0-10 L/min means total

leakage at 0.2 MPa.

A(Flow Accuracy):

Ax: x% is 10% of reading or better.

Oxygen Ration control With N2O pressure cut off valve

RO(Flow range of O2):

ROX/y/z

X: from 0.1-15 L/min means the max scale of the O2 tube.

y: from 15-22 L/min means max safety flow of O2 over the max scale.

Z: from 0 - 5mL/min means the O2 leakage with flow valve fully closed at 0.2 MPa.

RA(Flow range of Air):

RAX/y/z

x: from 0.1-15 L/min means the max scale of the Air tube.

y: from 15-22 L/min means max safety flow of Air over the max scale.

z: from 0-5 mL/min means the leakage with flow valve fully closed at 0.2 MPa.

CO(O2 Concentration): COx: x% is more than 25%

Optional function

1: Back light

2: O2 flush device

0: No optional